Skip to content

Weekly Device Health Report ​

The Weekly Device Health Report is a scheduled file with one row per cooler. It shows the health of each cooler's camera devices and hub over the last 7 days, the main issue found, and whether the cooler is still at its outlet.

How it works ​

  1. Data: at the scheduled time, the report covers every active cooler of the organization, using the last 7 days of images, pings, door openings and temperatures.
  2. Delivery: Settings lists one or more outputs. Each output has a file type, Excel or CSV, and a delivery method:
    • Email: the file is attached to one email for the definition's recipients. User-type recipients are not used.
    • SFTP: the file is uploaded to an SFTP folder.

By default, the file name contains the organization's code and the date and time the file was created. Settings can give a different report title. Dates use MM/DD/YYYY for organizations in a US or Canada time zone, and DD/MM/YYYY otherwise.

What the report shows ​

Each row is one cooler. A cooler can have up to two camera devices. The report labels their columns Vista1 and Vista2, whatever the device model.

ColumnsWhat they show
Location Code, Location Name, Street, City, Postal Code, Location StatusThe outlet and whether it is active.
L4 to L7Outlet groupings, such as market, outlet type, classification and distributor.
Chiller Model, Asset Serial NumberThe cooler.
Vista1 and Vista2: serial number, Last Image, Last Ping, Vista Battery, % of Vista BatteryEach camera's latest image and ping, and its battery voltage and charge.
Last 7 Days Avg TemperatureAverage temperature over the last 7 days, in the organization's temperature unit.
Purity Percentage, Last 7 Days Avg Purity, Last 7 Days Avg StockPurity and stock from the cooler images.
Last 7 Days Sum Door OpeningsNumber of door openings in the last 7 days.
Last 7 Days Purity SalesDoor openings × purity percentage ÷ 100.
Key product columnsPresent or Not Present for each of the organization's key products, from the latest image.
Distance, At Location, current street, city and postal codeWhether the cooler is still at its outlet (see below).
Lat, LongThe asset's latest position.
Vista1 - Primary issue, Vista2 - Primary issueThe main issue found for each camera (see below).
Vista1 - Reasons of issue, Vista2 - Reasons of issueThe latest note entered for the cooler.

When a cooler has two cameras, the temperature, purity, stock and door opening figures are the average of both.

At Location ​

At Location is No when the asset is further from the outlet than the cooler's displacement threshold. The report then looks up the asset's current street, city and postal code.

Primary issue ​

The first check that applies gives the primary issue:

Primary issueWhen
NoneAn approved image was received in the last 7 days. It is None - battery low when the camera battery is low.
HubThe hub has not pinged for a day, or its battery is below 50%.
VhThe hub's virtual hub (VH) has not pinged for a day.
Vista - Hub connection/ FuseThe camera has not pinged for a day, but its battery is fine.
Vista Connection & Battery?The camera has not pinged for a day and its battery is low.
Vista BatteryThe camera battery is low.
Vista - Capturing failedThe camera reported a failed capture in the last 7 days.
Last Image RejectedNo approved image in the last 7 days, and the latest image was rejected.
Upload/Angle?No approved image in the last 7 days, and the door was closed more than 4 hours after the latest image.
Doors?No approved image in the last 7 days, and none of the above.
UnKnownAs for Doors?, but the cooler has no door.